Study finds several variables can significantly increase the sampling error in total organic carbon (TOC) swab testing used for pharmaceutical cleaning verification.
Total organic carbon (TOC) swab is a commonly used cleaning verification method in the pharmaceutical manufacturing industry; however, according to a new paper, the sampling error leads to a large variation in TOC results.
In a study, scientists from Novo Nordisk and Technical University of Denmark used Monte Carlo simulation to quantify the sampling error of the TOC swab in actual sampling situations.
To establish sampling error, they assessed the variability of drug product recovery due to different analysts, residue concentrations, steel surface finishes and positions, as well as estimating of the given swab area. The simulation was based on a combination of different experiments in the laboratory combined with image analysis of areas swabbed with blue dye both in a laboratory setting and a formerly used production tank.
Recovery was determined using the limit of detection (LOD): the lowest concentration of an analyte in a sample that can be consistently detected with a stated probability (typically 95 percent certainty).
The researchers found that the sampling error leads to a large variation in TOC results. Including the variance from the different variables significantly increased LOD for areas in the laboratory; inclusion of the variables resulted in an LOD 2.4 times higher than the current LOD when only considering the analytical TOC method. Moreover, because of the large error variance (heteroscedasticity), the researchers were unable to determine an LOD for areas estimated in a tank.
The scientists also investigated which of the variables is most influential on the large sampling error. Prime on this list was sampling area, which, they wrote, is grossly overestimated, leading to artificially high TOC results. Residue concentration was the second most important factor, as it was found that recovery drastically decreased with diminishing concentrations of the given product.
The authors of the paper, published in the Journal of Pharmaceutical and Biomedical Analysis, concluded that their work is an “invitation to discuss and further investigate the TOC sampling error in the pharmaceutical industry”.
Print14 March 2024
26 February 2024
NovaMedica team wishes you a Merry Christmas and a Happy New Year!
26 December 2023
The Future of Pharmacy: How Advancements in Technology Are Transforming the Field
23 April 2024
Analysis Forecasts Up to 16.5% of Population Will Have Chronic Kidney Disease by 2032
23 April 2024
Microbial burden assessment of solid pharmaceutical products
22 April 2024
Seasonal variation of microbial contamination in pharmaceutical cleanrooms
22 April 2024